This study measured surface electromyography of the biceps brachii and triceps brachii during repeated drum playing with and without a drumstick to better understand activation of the upper arm muscles and inform the use of instrument playing for motor rehabilitation. A total of 40 healthy college students participated in this study. All participants were asked to strike a drum with their hand and with a drumstick at three different levels of stroke: soft, medium, and strong. The stroke order was randomly assigned to participants. A sound level meter was used to record the intensity of the drum playing. Surface electromyography signals were recorded at every hit during drum playing both with and without the drumstick in each of the three stroke conditions. The results demonstrated that the highest muscle activation was observed in both biceps brachii and triceps brachii with strong drum playing with and without the drumstick. A two-way repeated measures analysis of variance showed that there was a significant main effect for stroke intensity in muscle activation and produced sound level. While higher activation of the triceps brachii was observed for drum playing without a drumstick, no significant differences were found between the biceps brachii and sound level. This study demonstrated via surface electromyography data that greater muscle activation of the biceps brachii and triceps brachii does not occur with the use of drumsticks in drum playing. With the drum sound controlled, drum playing by hand can be an effective therapeutic intervention for the upper arm muscles.
Instrument playing as a system of sound production has received much attention in physical rehabilitation because it involves patterned physical movement. Instrument playing is highly effective as a therapeutic modality in rehabilitation because it induces repetitive physical movement in a predictable manner (
With regard to EMG responses during percussive instrument playing,
Most of this research focuses on the relationship between performance strategy and muscle activity with few studies exploring the perceptual properties of percussive sounds. One study investigated whether virtual and perceived sounds differed by the type of drum stroke, either normal or controlled (
Muscle activities measured by sEMG during drum playing have been widely studied from the trunk to the fingers; however, the information regarding muscle activation of the biceps brachii and triceps brachii during drum playing is still the blind spot for related academic areas, including rehabilitation and therapeutic use of instrument playing. Even though biceps brachii and triceps brachii are the main muscles in the upper arm, which would be activated by instrument playing for rehabilitation, little scientific evidence exists on their level of activity and relationship to sound intensity in drum playing. Thus, this study investigated sound intensity and muscle activation during drum playing.
Ethical approval was granted by the Ewha Womans University Institutional Review Board (approval number: 2012-07-03). The participants were informed of the procedure and provided written informed consent in accordance with the Declaration of Helsinki.
A total of 40 college students participated from universities located in central and remote areas of the Republic of Korea. All participants were nonmusic majors and had no history of muscle disease or current illness. The participants’ demographic characteristics are presented in
The 8-channel wireless QEMG-8 model (Laxtha Inc., Daejeon, Korea) was used to collect sEMG data when muscles were activated. The sEMG raw signals were measured at a sampling rate of 1,024 Hz and preamplified with a gain of 244. The amplified raw data were converted through an analog-to-digital converter with 12-bit resolution and recorded through Telescan ver. 2.91 (Laxtha Inc.) for data analysis. In this study, four channels were used to record sEMG signals from the biceps brachii and triceps brachii of the participant’s dominant arm.
For data analysis, the digitized raw sEMG data were stored on a personal computer using Telescan ver. 2.91 and band-pass FFT filtered from 10 Hz to 450 Hz with the offset value removed. The root mean squares (RMS) of sEMG amplitude for the biceps brachii and triceps brachii were calculated with a moving window of 0.117 sec. MVC, which was induced while producing maximum force during striking motion for each muscle, was also obtained to normalize sEMG data. Then the percentage MVC value for the averaged RMS value was analyzed to determine differences in sEMG signals among the three stroke conditions.
Disposable metal-plate electrodes with electrolyte gel coated Ag/AgCl disks (Ag-AgCl, 3M Inc., Hamden, CT, USA) were used to measure sEMG signals of the biceps brachii and triceps brachii of each participant’s dominant upper arm. The area on each participant’s skin where the electrode was placed with an interelectrode distance of about 20 mm was cleaned with alcohol to reduce skin resistance to less than 5 kΩ. A pair of electrodes was placed longitudinally on the belly of the biceps brachii and on the medial portion of the triceps brachii. The ground electrode was affixed to the back of the neck for electrical noise reduction. All the cables used for this study were shielded to eliminate electromagnetic interference and tied properly to the arms to prevent displacement of electrodes and to remove artifacts when playing the drum.
The XL2 analyzer (NTi Audio, Liechtenstein, Switzerland) is a sound-level meter that monitors and records live sound events and/or environmental noise. The XL2 with the M2230 microphone (NTi Audio) has the capability of correcting values between the loudest point of a live event and the measurement positions in accordance with DIN 15905-5 and SLV. In parallel with the wide band parameters, the XL2 measures the real-time spectrum either in 1/1 or 1/3 octave-band resolution.
A snare drum (Ludwig, 36×12.7 cm) was used, and its wire was removed to produce tom-tom sounds. The drumstick used to play the drum was standard (Preminum 7A) with a length of 39 cm and a diameter of 1.4 cm.
EMG signals were recorded from the biceps brachii and triceps brachii of each participant’s dominant upper arm in an acoustic anechoic chamber. Participants sat down on a chair facing the drum. Participants practiced playing the drum 5 times to get familiar with how strong to stroke in order to produce the three different levels of stroke (soft, medium, strong). Soft stroke, medium stroke, and strong stroke were defined by their decibel range as measured by the XL2 audio analyzer. Soft stroke ranged from 94 to 96 dB, medium stroke from 101 to 103 dB, and strong stroke from 108 to 110 dB. The examiner confirmed the participants’ posture and appropriate stroke level (
The participants were instructed to strike the drum with the drumstick 10 times for each stroke condition, for a total of 30 hits. Each drum strike was preceded by a visual cue generated at 3-sec intervals. There was a 10-sec break between sound conditions to refresh the muscles. Sound from the drum was muffled with soft lint to prepare for the next strike. These striking movements were repeated using the participant’s dominant arm but without the drumstick.
Drum playing can make various sounds and be generated from a variety of muscles such as the shoulder, upper arm, forearm, wrist, and fingers. However, to obtain data related to the flexion and extension of the upper arm to move the forearm for the purpose of rehabilitation, it is important to exclude any possible muscle movements other than from the biceps brachii and triceps brachii. To this end, a wrist brace was used to prevent a wrist snap from making any additional sound, and the upper arm was affixed to the side of the body to stop shoulder movement from being involved in the striking of the drum. A microphone (M2230) connected to an acoustic and audio analyzer (XL2) was placed 30 cm above the surface of the drum. The loudness of the drum sound and the strength of the muscle activations for each participant were measured for each condition.
Once participants completed the given task, the researcher saved the decibel sound pressure level and sEMG data in Volt. RMS value of sEMG data was selected and averaged before and after around 0.5 sec of each hit depending on the speed of each participant’s drum strikes, and decibel data were selected from the target hit (LEQmax) for further statistical analysis. The selected data were analyzed using a two-way repeated measures analysis of variance (ANOVA). The statistical tool used was IBM SPSS Statistics ver. 20.0 (IBM Co., Armonk, NY, USA).
For biceps brachii and triceps brachii, the muscle activation values were measured during striking of the drum with the use of the drumstick versus without the use of the drumstick for three different levels of stroke: soft, medium, and strong. With regard to muscle activation of biceps brachii, the highest muscle activation was observed in the condition of strong stroke regardless of whether the drumstick was used or not, followed by the medium and soft conditions, respectively. While greater sEMG values were observed for the biceps brachii when playing with a drumstick than when playing without the drumstick for the soft and medium stroke conditions, strong drum playing elicited greater muscle activation under the no drumstick condition. In terms of muscle activation of the triceps brachii, the highest sEMG data were observed for the strong stroke condition both with and without the drumstick. In each stroke condition, drum playing by hand led to higher muscle activation of the triceps brachii than using a drumstick. The sEMG data for each condition are summarized in
A two-way repeated measures ANOVA showed that for biceps brachii, the main effect for stroke condition reached statistical significance,
With regard to the triceps brachii, when playing the drum both with the drumstick and without the drumstick, the highest muscle activation was elicited in the strong stroke condition, followed by medium and soft stroke, respectively. When playing the drum without the drumstick, greater muscle activation was generated in all three stroke conditions, compared to when using a drumstick (
When striking the drum with and without the drumstick in each of the three levels of stroke (i.e., soft, medium, and strong), the produced sound intensity (dB) was measured. For each stroke condition, similar levels of sound intensity were measured when playing the drum with a drumstick and without a drumstick (
In the present study, we measured the amplitude of sEMG during striking motion involving extension and flexion of the dominant upper arm. Regarding the use of a drumstick, muscle activation of the biceps brachii was larger for soft and medium drum playing with the drumstick while the triceps brachii showed smaller activation for all three stroke conditions when playing with the drumstick. This is because drum striking is made mainly by the downward movement of the forearm, which involves the action of elbow extension, generated by the triceps brachii. In this movement, the biceps brachii mainly acts on controlling speed and direction against the movement of the triceps brachii.
Regardless of drumstick use, similar sound intensity levels were demonstrated in each striking condition. This finding suggests that the drumstick is not necessarily required to control the produced sound; however, less vibrotactile feedback is transmitted to the hand when using a drumstick. As revealed in
A possible use of the data from this study is in designing physical rehabilitation programs using drum playing. Alternating the produced sound level (dB) while playing a drum can be a practical intervention, and more effective therapeutic instrument playing can be provided if the required sound intensity level is controlled. It was generally believed that using drumsticks during drum playing involved more motor control since grabbing the drumstick was required; therefore, more muscle activation was expected. However, this study demonstrated via sEMG data that muscle activation is actually not associated with the use of drumsticks in drum playing. Thus, the use of drumsticks results in less movement being required and in a relatively reduced range of motion. The wider range of motion resulting from drum playing without drumsticks produces higher muscle activation making drum playing an ideal therapeutic treatment with the drum placed so that it addresses the upper limb targeted for rehabilitation.
In sum, the sound level should be loud enough to induce a certain level of muscle activation, and not using drumsticks is recommended when the therapist wants to focus on the triceps brachii muscle group. Also, hand drumming should be considered to increase muscle activation of the biceps brachii muscle group in the upper arms. Based on the results of this study, future research should investigate muscle activation and instrument playing in individuals with physical disabilities.
This work was supported in part by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (NRF-2013-R1A1A1013430) and in part by the National Research Foundation of Korea Grant funded by the Korean Government (NRF-2012-1788-001-2) and in part by the Soonchunhyang University Research Fund.
CONFLICT OF INTEREST
No potential conflict of interest relevant to this article was reported.
Experimental setup for the study. A microphone (M2230, NTi Audio, Liechtenstein, Switzerland) extended from an acoustic and audio analyzer (XL2, NTi Audio) was placed 30 cm above the surface of the drum. The loudness of the drum sounds and the strength of the muscle activations for each participant were measured throughout the three stroke conditions both with and without a drumstick. EMG, electromyography.
Electromyography maximal voluntary contraction (EMG MVC) (%) depending on the stroke and drumstick use for biceps brachii.
Electromyography maximal voluntary contraction (EMG MVC) (%) depending on the stroke and drumstick use for triceps brachii.
Sound intensity level (dB) depending on stroke and drumstick use.
Demographic characteristics (n=40)
Variable | Value |
---|---|
Gender, male:female | 22:18 |
Age (yr) | 21.3±1.8 |
Height (cm) | 169.5±9.5 |
Weight (kg) | 63.5±10.8 |
Body mass index (kg/m2) | 22.0±2.3 |
Values are presented as number or mean±standard deviation.
sEMG MVC (%) data depending on the sound intensity (n=40)
Muscle | Drumstick use | Level of stroke | sEMG MVC (%) |
---|---|---|---|
Biceps | Use | Soft | 31.9±23.0 |
Medium | 40.8±15.3 | ||
Strong | 51.6±42.2 | ||
No use | Soft | 24.5±15.3 | |
Medium | 34.5±30.9 | ||
Strong | 53.3±43.4 | ||
| |||
Triceps | Use | Soft | 15.2±15.1 |
Medium | 18.4±18.1 | ||
Strong | 35.5±44.9 | ||
No use | Soft | 22.4±20.9 | |
Medium | 34.2±31.6 | ||
Strong | 57.9±40.4 |
Values are presented as mean±standard deviation. sEMG MVC, surface electromyography maximal voluntary contraction.
Sound intensity level (dB) depending on the level of stroke and drumstick use (n=40)
Drumstick use | Level of stroke | Sound intensity level (dB) |
---|---|---|
Use | Soft | 95.4±4.9 |
Medium | 102.0±5.4 | |
Strong | 108.6±6.3 | |
| ||
No use | Soft | 94.0±5.8 |
Medium | 101.3±6.4 | |
Strong | 108.6±7.5 |
Values are presented as mean±standard deviation.